Since 1998 Galaxy Communication, Inc. has provided companies in the midwest with everything needed for a complete cabling infrastructure. This includes the cable, the jacks, the patch panels and the voice termination field. We also provide and install open racks, server racks, cable sleeves and cable ladder forCat 5 Testing Meters wiring closets and server rooms. And we're happy to share some of our knowledge and experience. Review the following sections to learn more about cabling infrastructure elements, and how Galaxy Communications, Inc. can help you.


Integrated Voice & Data

Galaxy Communications can enable customers of all sizes to integrate all their IT and communications systems thus offering a more cost effective and manageable system, with one point of contact for all cabling design, cabling installation, cable testing & certification and communications requirements.

Call or contact us today


Equipment Cost:

Email:
In Partnership with
Crest Capital Equipment Finance

     

Twisted Pair Cabling

Unshielded Twisted Pair

Unshielded Twisted Pair (UTP) has been designed for use in voice applications and local area networks. Because of the comparatively low cost this cable is widely used and is available in several different performance categories (Categories 3, 4, 5 and 6). Over 99% of our copper installations are UTP versus shielded twisted pair (STP), which is rarely used.

Electromagnetic interference is present in all types of cabling to some degree. There are two basic types of electromagnetic interference (EMI) that cable engineers worry about-electromagnetic emissions and electromagnetic immunity. Emissions refer to energy that is radiated by the cable, and immunity is the ability of the cable to reject outside signals. In local area networks (LANs), failure to properly manage EMI can have an adverse effect on the integrity of the signal being transmitted.

In an unshielded cable, careful design of the cable and the associated electronic equipment results in a "balance" of the currents in the two conductors of a pair. That is, the currents in the two conductors are equal in magnitude but flowing in opposite directions. Proper installation and termination of the cable is also critical to maintaining this balance.

In a balanced system, there is very little radiation of EMI since the external field from one conductor is effectively canceled by the external field from the other conductor of the pair. Generally, the more twists per foot of cable, the better the cable is electrically balanced. Category 5 cable has more twists per foot than Category 3 or 4 cables and, therefore, offers better protection from EMI problems.